Functions :
This signal conditioner provides the isolation for non-intrinsically safe
applications. The device supplies 2-wire and 3-wire transmitters, and can also be used with 2-wire
current sources. It transfers the analog input signal as two isolated current values.
Both outputs provide a 0/4 mA ... 20 mA current corresponding to the input signal.
The minimum available field voltage is 16 V at 20 mA. If necessary, the internal resistance of 250
Ω between terminals 8, 9 and 11, 12 can be used for conversion into a 0 V ... 5 V voltage
signal.
Features :
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Input 2-wire and 3-wire transmitters and 2-wire current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA ... 20 mA
- Accuracy 0.1 %
- Up to SIL3 acc. to IEC 61508